Open new windowRecommend selecting the PDF printerSee all data sheets

FIBRAPAN
TECHNICAL DATA-AVERAGE VALUES
Rev: 05/29/2018
PROPERTIESTEST METHOD UNITS THICKNESSES mm
7/9>9/12>12/19>19/30
DENSITY (*)EN 323kg/m3770/740735/720720/675675/655
INTERNAL BONDEN 319N/mm20,750,650,550,55
BENDING STRENGTH EN 310N/mm223222018
MODULUS OF ELASTICITY EN 310 N/mm22700250022002100
THICKNESS SWELLING 24 H EN 317%17151210
DIMENSIONAL MOVEMENT LENGTH/WIDTH EN 318%0,40,40,40,3
DIMENSIONAL MOVEMENT TICKNESS EN 318%6665
SURFACE SOUNDNESS EN 311N/mm21,21,21,21,2
SURFACE ABSORPTION (TWO FACES) EN 382-1mm> 150> 150> 150> 150
MOISTURE CONTENT EN 322%7+/-37+/-37+/-37+/-3
GRIT CONTENT ISO 3340 % Weight≤ 0,05≤ 0,05≤ 0,05≤ 0,05
FORMALDEHYDE CONTENT EN ISO 12460-5mg/100 g≤ 8≤ 8≤ 8≤ 8
REACTION TO FIRETABLA EN 13986:2004+A1:2015 IEN 13501-1ClassED-s2,d0(**)D-s2,d0(***)D-s2,d0
SOUND ABSORPTION COEFFICIENT (Α) (250 A 500 HZ)EN 13984:2004+A1:2015α 0.100.100.100.10
SOUND ABSORPTION COEFFICIENT (Α) (1000 A 2000 HZ)EN 13984:2004+A1:2015α 0.200.200.200.20
THERMAL CONDUCTIVITYEN 13984:2004+A1:2015W/ (m·K)0.130.130.120.12
AIRBORNE SOUND INSULATION (SURFACE MASS) (R)EN 13986:2004+A1:2015db22/2424/2626/2829/30
WATER VAPOUR PERMEABILITY DRY CUPEN 13986:2004+A1:2015μ 28/2725/24
WATER VAPOUR PERMEABILITY
WET CUP
EN 13986:2004+A1:2015
μ
18
17
16
15
BIOLOGICAL DURABILITY USEEN 13986:2004+A1:2015Class of use1111
CONTENT OF PENTACHLOROPHENOL (PCP)EN 13986:2004+A1:2015%<5<5<5<5
TOLERANCE ON NOMINAL DIMENSIONS
PROPERTIESTEST METHOD UNITS THICKNESSES mm
7/9>9/12>12/19>19/30
THICKNESS EN 324-1mm+/-0,2+/-0,2+/-0,2+/-0,3
LENGTH/WIDTH EN-324-1mm+/- 2 mm/m, máx +/- 5 mm.+/- 2 mm/m, máx +/- 5 mm.+/- 2 mm/m, máx +/- 5 mm.+/- 2 mm/m, máx +/- 5 mm.
SQUARENESS EN 324-2mm/m+/- 2+/- 2+/- 2 +/- 2
EDGE STRAIGHTNESS EN-324-2mm/m+/-1,5+/-1,5+/-1,5 +/-1,5
(*) VALUES TO BE CONSIDERED AS A ROUGH GUIDE ONLY.

(**) Mounted without an air gap behind the FIBRAPAN.
Mounted with a closed air gap not more than 22 mm behind the FIBRAPAN classificationD-s2,d2.
Classification E for any other more restrictive condition. Commission Decision 2007/348/EC.

(***) Mounted without an air gap behind the FIBRAPAN, or with a closed air gap behind the FIBRAPAN for thicknesses equal or greater than 15mm or with an open air gap behind the FIBRAPAN for thicknesses equal or greater than 18 mm.
Mounted with a closed air gap not more than 22 mm behind the FIBRAPAN classification D-s2,d2 in thicknesses between 10 and 18 mm. Commission Decision 2007/348/EC.

These physical-mechanical values improve/comply with those established by EN 622-5:2009 European Standard, Table 3. Requirements for general purpose boards for use in dry conditions (type MDF).

FIBRAPAN meets Class E1 requirements (analysed according to EN ISO 12460-5) as defined in EN 622-1:2003 European Standard.

FIBRAPAN is endorsed by AITIM Quality Labels.

FIBRAPAN STRIP meets these physical-mechanical characteristics declared.