Open new windowRecommend selecting the PDF printerSee all data sheets

FIBRANOR FB HIDROFUGO / FIBRAPAN FB HIDROFUGO
TECHNICAL DATA-AVERAGE VALUES
Rev: 05/25/2018
PROPERTIESTEST METHOD UNITS THICKNESSES mm
3 - 4>4 - 6>6 - 7>7 - 9>9 - 10
DENSITY (*)EN 323kg/m3890880880 - 860860860
INTERNAL BONDEN 319N/mm21,501,501,501,501,50
BENDING STRENGTH EN 310N/mm24040404040
MODULUS OF ELASTICITY EN 310 N/mm235003500350035003500
THICKNESS SWELLING 24 H EN 317%301812109
DIMENSIONAL MOVEMENT LENGTH/WIDTH EN 318%0,400,400,400,400,40
DIMENSIONAL MOVEMENT TICKNESS EN 318%66666
SURFACE SOUNDNESS EN 311N/mm2>1,2>1,2>1,2>1,2>1,2
SURFACE ABSORPTION (TWO FACES) EN 382-1mm>150>150>150>150>150
MOISTURE CONTENT EN 322%7+/-37+/-37+/-37+/-37+/-3
GRIT CONTENT ISO 3340 % Weight≤ 0,05≤ 0,05≤ 0,05≤ 0,05≤ 0,05
FORMALDEHYDE CONTENT EN ISO 12460-5mg/100 g≤ 8,0≤ 8,0≤ 8,0≤ 8,0≤ 8,0
REACTION TO FIRETABLA EN 13986:2004+A1:2015 IEN 13501-1ClassE (**)E (**)E (**)D-s2,d0 (***)D-s2,d0 (***)
SWELLING IN THICKNESS AFTER CYCLIC TEST (V313)EN 321 / EN 317%4025191916
INTERNAL BOND AFTER CYCLIC TEST (V313)EN 321 / EN 319N/mm20,350,350,300,300.25
SOUND ABSORPTION COEFFICIENT (Α) (250 A 500 HZ)EN 13984:2004+A1:2015α 0.100.100.100.100.10
SOUND ABSORPTION COEFFICIENT (Α) (1000 A 2000 HZ)EN 13984:2004+A1:2015α 0.200.200.200.200.20
THERMAL CONDUCTIVITYEN 13984:2004+A1:2015W/ (m·K)0.150.150.150.150.15
AIRBORNE SOUND INSULATION (SURFACE MASS) (R)EN 13986:2004+A1:2015dbNPD23242526
WATER VAPOUR PERMEABILITY DRY CUPEN 13986:2004+A1:2015μ 3434343333
WATER VAPOUR PERMEABILITY
WET CUP
EN 13986:2004+A1:2015
μ
23
23
23
22
22
BIOLOGICAL DURABILITY USEEN 13986:2004+A1:2015Class of use1 & 21 & 21 & 21 & 21 & 2
CONTENT OF PENTACHLOROPHENOL (PCP)EN 13986:2004+A1:2015%<5<5<5<5<5
TOLERANCE ON NOMINAL DIMENSIONS
PROPERTIESTEST METHOD UNITS THICKNESSES mm
3 - 4>4 - 6>6 - 7>7 - 9>9 - 10
THICKNESS EN 324-1mm+/-0,15+/-0,15+/-0,15+/-0,15+/-0,15
LENGTH/WIDTH EN-324-1mm+/- 2 mm/m, máx +/- 5 mm+/- 2 mm/m, máx +/- 5 mm+/- 2 mm/m, máx +/- 5 mm+/- 2 mm/m, máx +/- 5 mm+/- 2 mm/m, máx +/- 5 mm
SQUARENESS EN 324-2mm/m+/-2+/-2+/-2+/-2+/-2
EDGE STRAIGHTNESS EN-324-2mm/m+/-1,5+/-1,5+/-1,5+/-1,5+/-1,5
(*) VALUES TO BE CONSIDERED AS A ROUGH GUIDE ONLY.

(**) Commission Decision 2007/348/EC.

(***) Mounted without an air gap behind the FIBRANOR FB HIDROFUGO / FIBRAPAN FB HIDROFUGO of thickness ≥9 mm. Mounted with a closed air gap not more than 22 mm behind the FIBRANOR FB HIDROFUGO / FIBRAPAN FB HIDROFUGO of thickness ≥9 mm classification D-s2,d2. Classification E for any other less restrictive condition. Commission Decision 2007/348/EC.

These physical-mechanical values improve/comply with those established by EN 622-5:2009 European Standard, Table 4 " Requirements for boards for use in humid conditions" (Type MDF.H").

FIBRANOR FB HIDROFUGO / FIBRAPAN FB HIDROFUGO meet Class E1 requirements (analysed according to EN ISO 12460-5) as defined in EN 622-1:2003 European Standard.

(SELECT)