Open new windowRecommend selecting the PDF printerSee all data sheets

FIMAPAN E-Z
TECHNICAL DATA-AVERAGE VALUES
Rev: 05/20/2016
PROPERTIESTEST METHOD UNITS THICKNESSES mm
8/13>13/20>20/25>25/32>32/40
DENSITY (*)EN 323kg/m3700/650650/620620/595590/580575/560
INTERNAL BONDEN 319N/mm2≥ 0,40≥ 0,35≥ 0,30≥ 0,25≥ 0,20
BENDING STRENGTH EN 310N/mm2≥ 11≥ 11≥ 10,5≥ 9,5≥ 8,5
MODULUS OF ELASTICITY EN 310 N/mm2≥ 1800≥ 1600≥ 1500≥ 1350≥ 1200
THICKNESS SWELLING 2 H EN 317%≤ 6≤ 6≤ 6≤ 6≤ 6
SURFACE SOUNDNESS EN 311N/mm2≥ 0,8≥ 0,8≥ 0,8≥ 0,8≥ 0,8
MOISTURE CONTENT EN 322%8+/-38+/-38+/-38+/-38+/-3
FORMALDEHYDE CONTENT EN ISO 12460-5mg/100 g<3<3<3<3<3
REACTION TO FIRETABLA EN 13986:2004+A1:2015 IEN 13501-1ClassD-s2,d0**D-s2,d0***D-s2,d0D-s2,d0D-s2,d0
REACTION TO FIRETABLA EN 13986:2004+A1:2015 IEN 13501-1ClassDfl-s1****Dfl-s1Dfl-s1Dfl-s1Dfl-s1
SOUND ABSORPTION COEFFICIENT (Α) (250 A 500 HZ)EN 13984:2004+A1:2015α ≥ 0.10≥ 0.10≥ 0.10≥ 0.10≥ 0.10
SOUND ABSORPTION COEFFICIENT (Α) (1000 A 2000 HZ)EN 13984:2004+A1:2015α ≥ 0.25≥ 0.25≥ 0.25≥ 0.25≥ 0.25
THERMAL CONDUCTIVITYEN 13984:2004+A1:2015W/ (mK)≤ 0.14≤ 0.13≤ 0.12≤ 0.12≤ 0.12
AIRBORNE SOUND INSULATION (SURFACE MASS) (R)EN 13986:2004+A1:2015db≥ 24≥ 26≥ 28≥ 29≥ 31
WATER VAPOUR PERMEABILITY DRY CUPEN 13986:2004+A1:2015μ ≥ 16 / ≥ 50≥ 15 / ≥ 50≥ 15 / ≥ 50≥ 15 /≥ 50≥ 15 / ≥ 50
BIOLOGICAL DURABILITY USEEN 13986:2004+A1:2015Class of use11111
CONTENT OF PENTACHLOROPHENOL (PCP)EN 13986:2004+A1:2015%<5<5<5<5<5
TOLERANCE ON NOMINAL DIMENSIONS
PROPERTIESTEST METHOD UNITS THICKNESSES mm
8/13>13/20>20/25>25/32>32/40
THICKNESS EN 324-1mm+/-0,3+/-0,3+/-0,3+/-0,3+/-0,3
LENGTH/WIDTH EN-324-1mm+/-5+/-5+/-5+/-5+/-5
SQUARENESS EN 324-2mm/m+/-2+/-2+/-2+/-2+/-2
EDGE STRAIGHTNESS EN-324-2mm/m+/-1,5+/-1,5+/-1,5+/-1,5+/-1,5
(*) VALUES TO BE CONSIDERED AS A ROUGH GUIDE ONLY.

(**) Minimun thickness 9mm.Mounted without an air gap behind the FIMAPAN E-Z. Mounted with a closed air gap not more than 22 mm behind the FIMAPAN E-Z classificationD-s2,d2. Classification E for any other more restrictive condition. Commission Decision 2007/348/EC.

(***) Mounted without an air gap behind the FIMAPAN E-Z, or with a closed air gap behind the FIMAPAN E-Z for thicknesses equal or greater than 15mm or with an open air gap behind the FIMAPAN E-Z for thicknesses equal or greater than 18 mm. Mounted with a closed air gap not more than 22 mm behind the FIMAPAN E-Z classification D-s2,d2 in thicknesses between 10 and 18 mm. Commission Decision 2007/348/EC

(****)Minimun thickness 9 mm

These physical-mechanical values improve/comply with the P2 classification established in EN 312:2010 European Standard, Table 3. Boards for indoor applications (including furniture) in dry environments (Type P2). Requirements for the specified mechanical properties.

The quality of FIMAPAN E-Z is endorsed by AITIM Quality Label.

FIMAPAN E-Z meets Class E1 requirements (analysed according EN ISO 12460-5) as defined in EN 622-1:2010 European Standard.

FIMAPAN E-Z bears Certificate of Conformity with CARB phase 2 requirements regarding formaldehyde emission limits.

(SELECT)
Google+
Google+