Open new windowRecommend selecting the PDF printerSee all data sheets

PANNER
TECHNICAL DATA-AVERAGE VALUES
Rev: 12/07/2017
PROPERTIESTEST METHOD UNITS THICKNESSES mm
15
DENSITY (*)EN 323kg/m3660
INTERNAL BONDEN 319N/mm20.35
BENDING STRENGTH EN 310N/mm221
MODULUS OF ELASTICITY EN 310 N/mm22800
THICKNESS SWELLING 24 H EN 317%15
SURFACE SOUNDNESS EN 311N/mm21.0
MOISTURE CONTENT EN 322%8+/-3
FORMALDEHYDE CONTENT EN ISO 12460-5mg/100 g≤ 8,0
REACTION TO FIRETABLA EN 13986:2004+A1:2015 IEN 13501-1ClassC-s2, d0
SOUND ABSORPTION COEFFICIENT (Α) (250 A 500 HZ)EN 13984:2004+A1:2015α 0.10
SOUND ABSORPTION COEFFICIENT (Α) (1000 A 2000 HZ)EN 13984:2004+A1:2015α 0.25
THERMAL CONDUCTIVITYEN 13984:2004+A1:2015W/ (mK)0.13
AIRBORNE SOUND INSULATION (SURFACE MASS) (R)EN 13986:2004+A1:2015db27
WATER VAPOUR PERMEABILITY DRY CUPEN 13986:2004+A1:2015μ 50
WATER VAPOUR PERMEABILITY
WET CUP
EN 13986:2004+A1:2015
μ
16
BIOLOGICAL DURABILITY USEEN 13986:2004+A1:2015Class of use1
CONTENT OF PENTACHLOROPHENOL (PCP)EN 13986:2004+A1:2015%< 5
MECHANICAL DURABILITYEN 13986:2004+A1:2015Kmod KdefEN 1995-1:2004 3.1 & 3.2
TOLERANCE ON NOMINAL DIMENSIONS
PROPERTIESTEST METHOD UNITS THICKNESSES mm
15
THICKNESS EN 324-1mm+/- 0,3
LENGTH/WIDTH EN-324-1mm+/- 5
SQUARENESS EN 324-2mm/m+/- 2
EDGE STRAIGHTNESS EN-324-2mm/m+/-1,5
(*) VALUES TO BE CONSIDERED AS A ROUGH GUIDE ONLY.

These physical-mechanical values improve/comply with the P4 classification established in EN 312:2010 European Standard, Table 6. Structural boards used in dry conditions (Type P4). Requirements for the specified mechanical and swelling properties.

This product meets Class E1 requirements (analysed according EN ISO 12460-5) as defined in EN 312:2010 European Standard.

This product is endorsed by AITIM Quality Labels.

The quality of this product is endorsed by AITIM Quality Labels and CE Marking verified by AENOR, certificate number 0099/CPR/A65/0041.

(SELECT)