Open new windowRecommend selecting the PDF printerSee all data sheets

SUPERPAN BUILD
TECHNICAL DATA-AVERAGE VALUES
Rev: 04/20/2016
PROPERTIESTEST METHOD UNITS THICKNESSES mm
>10/13>13/20>20/25>25/32>32/40
DENSITY (*)EN 323kg/m3750720710700675
INTERNAL BONDEN 319N/mm20,600,600,550,500,45
BENDING STRENGTH EN 310N/mm22828262019
MODULUS OF ELASTICITY EN 310 N/mm235003500320030002800
THICKNESS SWELLING 24 H EN 317%101010109
DIMENSIONAL MOVEMENT LENGTH/WIDTH EN 318%0,40,40,40,40,4
DIMENSIONAL MOVEMENT TICKNESS EN 318%66666
SURFACE SOUNDNESS EN 311N/mm2>1,1>1,1>1,1>1,1>1,1
MOISTURE CONTENT EN 322%8+/-38+/-38+/-38+/-38+/-3
FORMALDEHYDE CONTENT EN ISO 12460-5mg/100 g≤ 8≤ 8≤ 8≤ 8≤ 8
SCREW HOLDING. EDGEEN-320N800800800800800
SCREW HOLDING. SURFACEEN-320N11001100110011001100
REACTION TO FIRETABLA EN 13986:2004+A1:2015 IEN 13501-1ClassD-s2,d0**D-s2,d0***D-s2,d0D-s2,d0D-s2,d0
REACTION TO FIRETABLA EN 13986:2004+A1:2015 IEN 13501-1ClassDfl-s1Dfl-s1Dfl-s1Dfl-s1Dfl-s1
SWELLING IN THICKNESS AFTER CYCLIC TEST (V313)EN 321 / EN 317%121211109
INTERNAL BOND AFTER CYCLIC TEST (V313)EN 321 / EN 319N/mm20,250,220,200,170,15
SOUND ABSORPTION COEFFICIENT (Α) (250 A 500 HZ)EN 13984:2004+A1:2015α 0,100,100,100,100,10
SOUND ABSORPTION COEFFICIENT (Α) (1000 A 2000 HZ)EN 13984:2004+A1:2015α 0,250,250,250,250,25
THERMAL CONDUCTIVITYEN 13984:2004+A1:2015W/ (mK)0,150,140,140,140,14
AIRBORNE SOUND INSULATION (SURFACE MASS) (R)EN 13986:2004+A1:2015db2628303132
WATER VAPOUR PERMEABILITY DRY CUPEN 13986:2004+A1:2015μ 50/6650/6650/6650/6650/66
BIOLOGICAL DURABILITY USEEN 13986:2004+A1:2015Class of use1 & 2 1 & 2 1 & 2 1 & 2 1 & 2
CONTENT OF PENTACHLOROPHENOL (PCP)EN 13986:2004+A1:2015%<5<5<5<5<5
MECHANICAL DURABILITYEN 13986:2004+A1:2015Kmod KdefTabla 3.1, EN 1995-1:2004;Tabla 3.2, EN 1995-1:2004; Tabla 3.1, EN 1995-1:2004;Tabla 3.2, EN 1995-1:2004; Tabla 3.1, EN 1995-1:2004;Tabla 3.2, EN 1995-1:2004; Tabla 3.1, EN 1995-1:2004;Tabla 3.2, EN 1995-1:2004; Tabla 3.1, EN 1995-1:2004;Tabla 3.2, EN 1995-1:2004;
TOLERANCE ON NOMINAL DIMENSIONS
PROPERTIESTEST METHOD UNITS THICKNESSES mm
>10/13>13/20>20/25>25/32>32/40
THICKNESS EN 324-1mm+/-0,30+/-0,30+/-0,30+/-0,30+/-0,30
LENGTH/WIDTH EN-324-1mm+/-5+/-5+/-5+/-5+/-5
SQUARENESS EN 324-2mm/m+/-2+/-2+/-2+/-2+/-2
EDGE STRAIGHTNESS EN-324-2mm/m+/-1,5+/-1,5+/-1,5+/-1,5+/-1,5
(*) VALUES TO BE CONSIDERED AS A ROUGH GUIDE ONLY.

(**) Mounted without an air gap behind the SuperPan Build. Mounted with a closed air gap not bigger than 22 mm behind the SuperPan Build classificationD-s2,d2. Classification E for any other more restrictive condition. Commission Decision 2007/348/EC

(***) Mounted without an air gap behind the SuperPan Build, or with a closed air gap behind the SuperPan Build for thicknesses equal or greater than 15mm or with an open air gap behind the wuperPan Tech P5 for thicknesses equal or greater than 18 mm . Mounted with a closed air gap not bigger than 22mm behind the SuperPan Build classification D-s2,d2 in thicknesses between 10 and 18 mm. Commission Decision 2007/348/EC.

These physical-mechanical values improve/comply with the P5 classification established in EN 312:2010 European Standard, Tables 7 and 8. Structural boards used in moist environments (Type P5). Requirements for the specified mechanical and swelling properties. Requirements for use in humid contitions.

SuperPan Build meets Class E1 requirements (analysed according EN ISO 12460-5) as defined in EN 312:2010 European Standard.

SuperPan Build holds CE Certificate of conformity of the factory production control issed by the European Notified Body AENOR.